Vial Hot Air Circulation Sterilizing Tunnel
Main application
Tunnel type hot air circulation sterilization tunnel is mainly suitable for drying,sterilizing and removing heat sources of vials bottles in pharmaceutical enterprises.It can also be used for drying,sterilizing and removing heat sources of containers such as ampoule bottles and oral liquid bottles.
Characterstics
This machine is a tunnel structure,and the whole tunnel is divided into three parts:preheating zone,high temperature sterilization zone and cooling zone.The use of hot air laminar flow principle and high temperature sterilization process for the container drying,sterilization,heat source,the use of negative pressure sealing structure,coupled with the unique hot air diversion and other core technologies,thermal distribution,is the most popular in today’s world of the drying and sterilization machine.
Technical parameters
Product model |
HSDH600/3600 |
HSDH600/4250 |
HSDH600/5000 |
HSDH800/4250 |
HSDH800/5000 |
HSDH800/6500 |
Suitable sizes(ml) |
2-30ml(vial) |
|||||
Output (pcs/min) |
300-500 |
400-600 |
480-700 |
550-800 |
680-1000 |
800-1200 |
Mesh belt width(mm) |
600 |
600 |
600 |
800 |
800 |
800 |
Temperature (°C) |
280-350°C(Adjustable) |
|||||
Breakage rete (°C) |
?0.05% |
|||||
Power supply |
380V 50Hz |
|||||
Power capacity(kW) |
60 |
71 |
81 |
86 |
91 |
108 |
Total weight(kg) |
4500 |
4800 |
5200 |
5500 |
5800 |
6500 |
Overall dimensions(mm) |
3600x1750x2245 |
4250x1750x2245 |
5000x1750x2245 |
4250x1950x2245 |
5000x1950x2245 |